AT526G Fuel Cell Meter
ACTIVE
RS232HANDLER
RS485OPTIONS
DATA LOGGER
OVERVIEW
    FEATURES
    SPECIFICATIONS
    ParametersACR, DCV
    AccuracyR:0.5% V:0.01%
    RangeR:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
    Signal SourceAC 1kHz,Test current:<150mA
    RangeAutomatic & Manual, 7 ranges
    Speed30 times/s, 10 times/s, 1 times/s
    Result Displayshow, ΔABS,Δ%,θ, sorting results
    Display MaxR:33,000 V:400,000
    Adjustmentshort-circuit reset for all range
    Comparator18 bin sorting, RHI/RNG/RLO output VHI/VNG/VLO output Absolute tolerance ±TOL sorting Percent tolerance TOL sorting Sequence comparison sorting
    TriggerInternal, Manual, External, Remote
    InterfaceRS-232C , Handler(PLC)
    OptionsATL609 Test Fixture
    PowerV:195VAC~245VAC Fre:50Hz Power:15VA
    Dimensions264 x107x350 mm
    Mass4KG
    AccessoriesATL502 Kelvin test leads、 ATL108 RS232 communication cable,ATL502A test probe
    Other functionsDetection of damage test wire, TFT-LCD display, keypad lock and data hold function, internal memoryand u-disk record
    DOCUMENTATION
    NONE
    ACCESSORIES
    STANDARDS
    NONE
    OPTIONS
    NONE
    SOFTWARE
    NONE
    RELATED PRODUCTS

    Compare

    AT520

    • Parameters: AC Resistance , DC voltage
    • Accuracy: R: 0.3%, V: 0.05%
    • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
    • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
    • Range: Automatic and manual with 6 ranges

    Compare

    AT520L

    • Parameters: AC Resistance , DC voltage
    • Accuracy: R: 0.3%, V: 0.05%
    • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
    • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
    • Range: Automatic and manual with 6 ranges

    Compare

    AT525

    • Parameters: ACR DCV
    • Accuracy: R:0.8%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
    • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
    • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
    • Range: Automatic, Manual, Norminal, 4 ranges

    Compare

    AT526

    • Parameters: ACR, DCV
    • Accuracy: R:0.5% V:0.01%
    • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
    • Signal Source: AC 1kHz,Test current:<150mA
    • Range: Automatic & Manual, 7 ranges

    Compare

    AT526B

    • Parameters: ACR, DCV
    • Accuracy: R:0.5% V:0.01%
    • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
    • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
    • Range: Automatic & Manual , 5 ranges

    Compare

    AT526C

    • Parameters: AC Resistance, DC voltage
    • Accuracy: Resistance:0.5% ; Voltage:0.01%
    • Range: Resistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
    • Signal Source: AC 1kHz,Test current:<150mA
    • Range: 7 ranges, auto & manual

    Compare

    AT527

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
    • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

    Compare

    AT527A

    • Parameters: ACR, DCV
    • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
    • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
    • Signal Source: 1kHz, stable frequency: 20ppm
    • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

    Compare

    AT527B

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
    • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
    • Signal Source: 1kHz, Frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

    Compare

    AT527H

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
    • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

    Compare

    AT527L

    • Parameters: ACR, DCV
    • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
    • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
    • Signal Source: 1kHz, frequency stability: 20ppm
    • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

    Compare

    AT528

    • Parameters: ACR, DCV
    • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
    • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
    • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
    • Range: 6 ranges, automatic, manual, nominal

    Compare

    AT528L

    • Parameters: ACR, DCV
    • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
    • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
    • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
    • Range: 4 ranges, automatic, manual, nominal
    Privacy | Term of Use | Help
    ©2005-2021 Changzhou Applent Instruments Ltd. 苏ICP备13026254号