AT527B AC Low ohm Meter (Battery Internal Resistance Meter)
ACTIVE
RS232RS485USB-232HANDLER
GPIBLANOPTIONS
SCPIMODBUSTCP
DATA LOGGERUSB-DISK
OVERVIEW
    AT527B adopts high-performance 32-bit ARM microprocessor-controlled micro-benchtop instrument for automatic real-time detection. The instrument uses a 4.3-inch true-color LCD display, which is operated in a full-touch mode, providing a brand-new instrument interaction experience.

    The instrument can test 0.0001mΩ~3.3kΩ resistance, 0.00001~800.000V DC voltage, resistance 33000 display digits, voltage 800000 display digits. AT527B has the characteristics of high precision, high resolution and ultra-high-speed measurement at the same time, providing 0.5% resistance accuracy and 0.01% voltage accuracy, and the measurement speed can reach 55 times/second.

    The instrument is used for professional sorting function. It is equipped with a Handler (PLC) interface as standard, and independently outputs resistance HIGH/IN/LOW signal and voltage HIGH/IN/LOW signal, which can fully cope with high-speed automatic sorting system to complete automatic assembly line test. At the same time, the enhanced IO signal can directly drive the power relay and signal relay.

    The instrument has built-in RS-232C interface and USB-232 interface. The instrument comes standard with general data acquisition software, with its own database function and Excel export function, which can be effectively used for remote control and data acquisition and analysis.

    The instrument uses enhanced computer remote control command set of Anbai Instrument, compatible with SCPI(Standard Command for Programmable Instrument) and Modbus Protocal(Modbus has become National Standard GB/T19582-2008). It is used for automatic sorting system to fullfill full automatic assembly line inspection, capable of completing remote control and data collection function with high efficiency.

    Adopting new and improved designed AC resistance test principle, it can be used for almost all battery internal resistance test, including the assembly line inspection of lead acid battery, button battery, Lithium battery, etc.,
FEATURES
  • 33000 AC resistance readings, 800,000 DC voltage reading
  • Resistance test range: 0.0001mΩ~3.3000kΩ
  • Voltage test range: 0.00001V~800.000VDC
  • 0.5% resistance accuracy
  • 0.01% voltage accuracy
  • HANDLER interface
  • RS-232C and USB communication interface
  • U disk real-time storage full touch operation
SPECIFICATIONS
ParametersACR, DCV
AccuracyAccuracy of resistance 0.5%,voltage accuracy 0.01%
RangeTest range 0.0001mΩ~3kΩ & 0.00001~800.000V
Signal Source1kHz, Frequency stability: 20ppm
Range3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal
SpeedAll channels open with manual operation: slow 3 times/s, medium: 20 times/s, fast: 40 times/s, high speed 70 times/s
Result Displayshow,ΔABS,Δ%,θ sorting result
Display MaxR: 33,000 V:800,000
AdjustmentShort -circuit reset full range
Comparatorsorting function. RHI/RNG/RLO output, VHI/VNG/VLO output, NG/OK output. Compare way:Absolute value tolerance ±TOL sorting: the absolute deviation between the measured value and the nominal value is compared with the limits of each file. Percent tolerance %TOL sorting: the percentage deviation between the measured value and the nominal value is compared with the limits of each file. Sequential comparison sorting: the measured value is directly compared with the upper and lower limits
TriggerInternal, Manual, External, Remote
Cantact CheckingBroken Wire Detection and Open Detection
InterfaceHANDLER, RS-232C, USB
OptionsATL527A
PowerV: 195VAC~245VAC Fre:50Hz power:15VA
Dimensions264 x107 x350 mm
Mass4KG
AccessoriesATL527 kelvin test cable ,ATL108 RS232 communication cable
Other functions4.3 inch TFT-LCD color display, full touch operation
APPLICATIONS
    Various contact resistance tests
    Determination of deterioration and life evaluation of alkaline batteries, lead storage batteries, and lithium batteries
    Delivery inspection
    Super Capacitor Equivalent Resistance (ESR) Measurement
DOCUMENTATION
DOCUMENTS
DATASHEET CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATL527

ATL527

AT527 kelvin test clip

ATL527A

ATL527A

AT527 Probe test pen

ATL801

ATL801

RS232C Cable(2m)

OPTIONS

ATL527B

ATL527B

AT527 Probe test pen

SOFTWARE
AT527 Datalogger
Rev.A1.0

Application

FREEWARE

9.2MB

MSI

RELATED PRODUCTS

Compare

AT520L

  • Parameters: AC Resistance , DC voltage
  • Accuracy: R: 0.3%, V: 0.05%
  • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
  • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
  • Range: Automatic and manual with 6 ranges

Compare

AT525

  • Parameters: ACR DCV
  • Accuracy: R:0.5%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
  • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
  • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
  • Range: Automatic, Manual, Norminal, 4 ranges

Compare

AT526

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT526B

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
  • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
  • Range: Automatic & Manual , 5 ranges

Compare

AT526C

  • Parameters: AC Resistance, DC voltage
  • Accuracy: Resistance:0.5% ; Voltage:0.01%
  • Range: Resistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: 7 ranges, auto & manual

Compare

AT527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT527A

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT527H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

Compare

AT528

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 6 ranges, automatic, manual, nominal

Compare

AT528L

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 4 ranges, automatic, manual, nominal

Compare

AT526G

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT527F

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT572B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527K

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1500.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT529

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529A

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~200.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~800.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3300.00Ω & 0.000001V~1000.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT527S

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~2000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT2527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT2527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~60.0000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.
Privacy | Term of Use | Help