AT527H AC Low ohm Meter (Battery Internal Resistance Meter)
ACTIVE
RS232USB-232HANDLER
RS485GPIBOPTIONS
USB-DISK
OVERVIEW
    AT527H features a fully automated, real-time, micro-desktop instrument controlled by a high-performance 32-bit ARM microprocessor. Instrument used 4.3 inches true color LCD display, full touch operation, a new instrument interactive experience.

    This instrument can test 0.0001mΩ~3.3kΩ resistance, 0.00001V~1000.000V DC voltage, maximum resistance 33000 display digits, and maximum voltage 100000 display digits. The AT527H combines high-precision, high-resolution and ultra-high-speed measurement with 0.5% resistance accuracy and 0.01% voltage accuracy up to 55 times per second.

    The instrument is used for professional sorting function, standard Handler (PLC) interface, separate output resistance HIGH / IN / LOW signal and voltage HIGH / IN / LOW signal, can fully cope with high-speed automatic sorting system to complete the automatic pipeline test, At the same time, the enhanced IO signal can directly drive the power relay and signal relay.

    The instrument has built-in RS-232C interface and USB-232 interface. The instrument is equipped with universal data acquisition software, comes with database function and Excel.

    The export function can be effectively applied to remote control and data acquisition and analysis.

    The instrument uses Amber Instruments to enhance the computer remote control instruction set, compatible with SCPI (StandardCommandforProgrammable

    Instrument can control the standard command set of the instrument and Modbus protocol (Modbus has become the national standard GB/T19582-2008) applied to the automatic sorting system to complete the automatic pipeline test. Efficiently complete remote control and data acquisition functions.

    The newly improved AC resistance test principle can be used for the internal resistance test of almost all batteries, including the pipeline inspection of various batteries such as lithium batteries, lead-acid batteries, and button batteries.
FEATURES
  • 33000 AC resistance readings, 1000,00DC voltage reading
  • Resistance test range: 0.0001mΩ~3.3000kΩ
  • Voltage test range: 0.00001V~400.000VDC
  • 0.5% resistance accuracy
  • 0.01% voltage accuracy
  • HANDLER interface
  • RS-232C and USB communication interface
  • U disk real-time storage full touch operation
SPECIFICATIONS
ParametersACR, DCV
AccuracyAccuracy of resistance: 0.5%,voltage: 0.01%
RangeTest range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
Signal Source1kHz, frequency stability: 20ppm
Range3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.
SpeedAll channels open and manual operation: slow 3 times/s, medium 20 times/s, fast 40 times/s , high-speed 70 times/s.
Result Displayshow, ΔABS,Δ%,θ, sorting result
Display MaxR:33,000 V:800,000
Adjustmentshort-circuit reset full range
Comparatorsorting function: RHI/RNG/RLO output, VHI/VNG/VLO output, NG/OK output. compare way:Absolute value tolerance ±TOL sorting: the absolute deviation between the measured value and the nominal value is compared with the limits of each file. Percent tolerance %TOL sorting: the percentage deviation between the measured value and the nominal value is compared with the limits of each file. Sequential comparison sorting: the measured value is directly compared with the upper and lower limits
TriggerInternal, Manual, External and remote
InterfaceHANDLER, RS-232C, USB
OptionsATL527A
PowerV:195VAC~245VAC Fre:50Hz Power:15VA
Dimensions264 x107x350mm
Mass4KG
AccessoriesATL527 kelvin test cable, ATL108 RS232 cable
Other functions4.3 inch TFT-LCD color display, full touch operation
APPLICATIONS
    Various contact resistance tests
    Determination of deterioration and life evaluation of alkaline batteries, lead storage batteries, and lithium batteries
    Battery factory inspection
    Super Capacitor Equivalent Resistance (ESR) Measurement
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATL527

ATL527

AT527 kelvin test clip

ATL527A

ATL527A

AT527 Probe test pen

ATL801

ATL801

RS232C Cable(2m)

OPTIONS

ATL527B

ATL527B

AT527 Probe test pen

SOFTWARE
AT527 Datalogger
Rev.A1.0

Application

FREEWARE

9.2MB

MSI

RELATED PRODUCTS

Compare

AT520

  • Parameters: AC Resistance , DC voltage
  • Accuracy: R: 0.3%, V: 0.05%
  • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
  • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
  • Range: Automatic and manual with 6 ranges

Compare

AT520L

  • Parameters: AC Resistance , DC voltage
  • Accuracy: R: 0.3%, V: 0.05%
  • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
  • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
  • Range: Automatic and manual with 6 ranges

Compare

AT525

  • Parameters: ACR DCV
  • Accuracy: R:0.8%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
  • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
  • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
  • Range: Automatic, Manual, Norminal, 4 ranges

Compare

AT526

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT526B

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
  • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
  • Range: Automatic & Manual , 5 ranges

Compare

AT526C

  • Parameters: AC Resistance, DC voltage
  • Accuracy: Resistance:0.5% ; Voltage:0.01%
  • Range: Resistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: 7 ranges, auto & manual

Compare

AT527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT527A

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT527B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

Compare

AT528

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 6 ranges, automatic, manual, nominal

Compare

AT528L

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 4 ranges, automatic, manual, nominal

Compare

AT526G

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges
Privacy | Term of Use | Help