AT58612 Film capacitor charge and discharge tester
ACTIVE
OVERVIEW
    FEATURES
    SPECIFICATIONS
    ● Power module※ Programmable constant voltage and constant current source ※
            Input voltage380V AC 50Hz
            Output voltage range100~1200V(This parameter is for reference only and can be customized according to requirements)
            Output current range10A
            Maximum output power12000W
            Power module voltage setting/readback accuracy± 2%, ± 5dgt (set value=charging and discharging set voltage, the readback value can be viewed when the internal parameters are turned on)
    ● Charging module※ Constant current charging module ※
            Constant current charging rangeAbout 9A
    ●Discharge moduleElectronic load
            Pulse carrying current rangeMAX 3200A (theoretical value, actual value depends on external inductance and measured capacitance, internal 3200A current limitation of the instrument can reduce the damage rate of misoperation)
            Charge and discharge parameters (user specific parameters)
            Discharge modeExternal inductor discharge
            TriggerInternal/PLC/232/485
            Voltage100~1200V
            Measurement timing (single product measurement time)1~1200
            Test frequency (charge discharge frequency)1Hz ~200Hz
            Discharge current settingInternal fixed limit MAX 3200A (theoretical value, actual value depends on external inductance and measured capacitance, internal 3200A current limit of the instrument can reduce the damage rate of misoperation)
            Capacitance capacity20μF~300μF, this parameter needs to be set by the user according to the actual situation
            External inductance12μH~100μH, this parameter needs to be set by the user according to the actual situation
            Open circuit detectionSample the discharge current, and if the sampled value is particularly small, determine an open circuit
            Charging undervoltage detectionYes, it can detect incorrect products and avoid damaging the instrument in case of timing errors on the machine
            Over temperature detectionYes
    InterfaceRS232/RS485/handler interface (for connecting to PLC)
    Programming languageSCPI and Modbus(RTU)
    Power SupplyThree phase five wire
    PowerMaximum 12000W
    Weight100kg
    DOCUMENTATION
    NONE
    ACCESSORIES
    STANDARDS
    NONE
    OPTIONS
    NONE
    SOFTWARE
    NONE
    Privacy | Term of Use | Help
    ©2005-2024 Changzhou Applent Instruments Ltd. 苏ICP备13026254号