AT2617 Capacitance Meter
ACTIVE
RS232RS485USB-232HANDLER
GPIBOPTIONS
SCPIMODBUS
DATA LOGGERUSB-DISK
OVERVIEW
    FEATURES
    SPECIFICATIONS
    DOCUMENTATION
    DOCUMENTS
    USER'S GUIDE CHINESE
    ACCESSORIES
    STANDARDS
    NONE
    OPTIONS
    NONE
    SOFTWARE
    NONE
    RELATED PRODUCTS

    Compare

    AT2811

    • Test Functions: L,C,R,Z,D,Q
    • Accuracy: 0.25%
    • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
    • Measurement Range: Auto/Hold, 6 ranges
    • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

    Compare

    AT2816A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05%
    • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT2816B

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05%
    • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT2817

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.05%
    • Measurement Frequency: 50Hz~200kHz (16 Points)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40/10/3 times/s

    Compare

    AT2817A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.05%
    • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40/10/3 times/s

    Compare

    AT2818

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.05%
    • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

    Compare

    AT3810A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
    • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT3816A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
    • Measurement Frequency: 10Hz~200kHz (Resolution 0.01Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT3817A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
    • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT3818

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
    • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT610D

    • Test Functions: C,D
    • Accuracy: 0.1%
    • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
    • Measurement Range: AUTO/HOLD 6 Ranges
    • Measurement Speed: 3times/s, 8 times/s, 20 times/s

    Compare

    AT810

    • Test Functions: L,C.R,Z,D,Q
    • Accuracy: 0.1%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
    • Measurement Range: AUTO/HOLD, 6 Ranges
    • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

    Compare

    AT810A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05%
    • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

    Compare

    AT810D

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.2%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
    • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
    • Measurement Speed: 2 times/s, 5 times/s

    Compare

    AT811

    • Test Functions: L,C,R,Z,D,Q
    • Accuracy: 0.25%
    • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
    • Measurement Range: Auto/Hold, 6 ranges
    • Measurement Speed: 5 次 / 秒,11 次 / 秒

    Compare

    AT817D

    • Test Functions: L,C,R,Z,D,Q
    • Accuracy: 0.1%
    • Measurement Frequency: 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
    • 20kHz,40kHz,50kHz, 100kHz
    • Measurement Range: AUTO/HOLD 6 Ranges

    Compare

    AT825

    • Test Functions: L,C,R,Z
    • Accuracy: 0.2%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
    • Measurement Range: -
    • Measurement Speed: 4 times/s, 1.5 times/s

    Compare

    AT826

    • Test Functions: L,C,R,Z
    • Accuracy: 0.2%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    • Measurement Range: -
    • Measurement Speed: 4 times/s, 1.5 times/s
    Privacy | Term of Use | Help
    ©2005-2021 Changzhou Applent Instruments Ltd. 苏ICP备13026254号