| Measurement Functions | AC/DC withstand voltage, insulation resistance, grounding, leakage current, AC power, startup(optional) |
| Interface | USB-HOST, RS232/RS485, HANDLER, ALARM, REMOTE |
| Standard Configuration | Three-color alarm lamp; remote control switch, capable of connecting external start and stop signals |
| Protect Function | OV/OC |
| Other Functions | 9‘’ LCD |
| AC Withstand Voltage | ● |
| Rate Ouput | 5kV AC,100mA |
| Output Power | 200VA |
| Output Voltage | 100 ~ 5000 V AC Resolution:resolution 1V |
| Voltage Accuracy | ±(1.5% of set value + 3V) |
| Output Frequency | 50Hz / 60Hz |
| Measurement Current | 0.002-9.999mA-100.00mA Resolution:0.001mA/0.01mA |
| Current Accuracy | 1.5% × Reading + 0.01mA |
| Rising Time | 1s-999s |
| Testing Time | 1s-999s |
| Falling Time | 1s-999s |
| DC Withstand Voltage | ● |
| Rate Output | 6kV DC/10mA |
| Output Power | 120VA |
| Output Voltage | 100~6kV DC Resolution: 1V |
| Voltage Accuracy | ±(1.5% of set value + 3V) |
| Current Accuracy | 2% × Reading + 0.01mA |
| Rising Time | 1s-999s |
| Testing Time | 1s-999s |
| Falling Time | 1s-999s |
| Insulation Resistance | ● |
| Rate Output | 1kV/10GΩ |
| Output Voltage | 100~1000V Resolution:1V |
| Voltage Accuracy | ±(1.5% of set value + 3V) |
| Measurement Range | 0.1MΩ-10GΩ |
| IR Accuracy | 100-499V: 1MΩ~16GΩ: ±(5% of reading + 0.5MΩ); 1GΩ~10GΩ (for reference only, no accuracy requirement) 500-1000V: <100MΩ~1GΩ: ±(3% of reading + 2MΩ); 1GΩ~10GΩ: ±(10% of reading + 5MΩ) |
| Testing Time | 1s-999s |
| Ground Impedance | ● |
| Rate Output | 2.0-40A, 10.0-600mΩ |
| Output Current | 40A |
| Output Voltage | <12V |
| Frequency | 50Hz / 60Hz |
| Testing Time | 1s-999s |
| Leak Current | ● |
| Test Voltage Output | Single-phase, requires external isolation transformer or variable frequency power supply to provide voltage and frequency required for testing |
| Test Type | G-L,G-N,AUTO(G-L,G-N) |
| AC Voltage Measurement | Range:60.0V-300.0V Resolution:0.1V Accuracy: ±(1.5%×Reading+3V) |
| AC Current Measurement | Range:0.000mA-20.00mA Resolution:0.001mA/0.01mA Accuracy:±( 1.5% × Reading + 5 Digits) |
| Testing Time | 1s-999s |
| AC Power | ● |
| AC Voltage Output | Single-phase, requires external isolation transformer or variable frequency power supply to provide voltage and frequency required for testing |
| AC Voltage Measurement | Range:60.0V -300.0V Resolution: 0.1V Accuracy: ±(0.25%×Reading+0.25%×Range) |
| AC Current Measurement | Range:0-30A Resolution:0.001A/0.01A Accuracy: ±(0.25%×Reading+0.25×Range) |
| Power Measurement | Range:0-6000W Resolution:0.1W/1W Accuracy: ±(0.25%×Reading+0.25×Range) |
| Testing Time | 1s-999s |
| Testing Time | 1s-999s |
| Startup | optional |
| AC Voltage Measurement | 60.0V-300V, Resolution0.1V; Accuracy: ±(0.25%×Reading+0.25×Range) |
| AC Current Measurement | 0-30A |
| Current Setup Range | Upper limit: 0.001–30.00 A, Lower limit: 0.000–30.00 A |
| Power Supply | 220V~240V AC 47.5~52.5Hz 300VA |
| Dimension & Weight | 470 x 133 x491(mm) 30kg |