Input Rating | 150W、150V、30A |
CC | 0-3A:Resolution:0.0001A Accuracy:0.05% 0-30A:Resolution:0.001A Accuracy:0.1% |
CV | 0-18V:Resolution:0.001V Accuracy:0.05% 0-150V:Resolution:0.01V Accuracy:0.05% |
CP | 0-100W:Resolution:0.001W Accuracy:0.1% Above 100W:Resolution:0.01W Accuracy:1% |
CR | 0.1~99Ω:Resolution:0.01Ω Accuracy:1% 100~4kΩ:Resolution:0.1Ω Accuracy:1% |
Accuracy | Ampere meter accuracy:0.1%,voltmeter accuracy:0.05%, |
Short Circuit | Current: aboout 30A; internal resistance: about 40mΩ |
Dynamic Testing | 0.1Hz~1kHz |
List Test | 10 files, 100 steps/ file |
Test File | 10 files, 20 steps/file |
Battery Test | MAX 999AH |
Interface | RS232C |
Optional | RS485 |
Protect | 5 level security protect |
Other Functions | 3.5 inch true color LCD display, 4W remote test,intelligent cooling |
Power Supply | Voltage:198V-252VAC, Fre:48.5Hz ~ 52.5Hz, Power:15VA |
Dimension & Weight | 264*107*350mm / 5KG |