AT827 Handheld LCR Digital Meter
ACTIVE
Send Email to us
USB-HIDUSB-232
SCPI
DATA LOGGERUSB-DISK
OVERVIEW
    FEATURES
    SPECIFICATIONS
    Test FunctionsC-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
    Accuracy0.2%
    Measurement Frequency50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz
    Display RangeL: 0.01uH-9999H
    C: 0.01pF - 9999uF
    R,Z: 0.0001Ω - 99.99MΩ
    D:0.0001–9.999
    Q:0.0001~999.9
    Source Resistance100Ω
    Trigger ModeInternal
    Comparator1 sets, compare main parameters
    Comparator ModeSEQ/ABS/PER
    Adjustmentopen/short clear zero
    FilesUSB storage
    InterfaceUSB-HID
    ProtocolSCPI
    Other FunctionsTouch screen; USB-HID communication, compatible SCPI ; English & Chinese language, adjustable back light, auto power off(APO)
    Power Supplyinput: 100-240V,50Hz, 0.35A, output:9V 1A DC
    Dimension & Weight90*195*35.5mm
    400g
    DOCUMENTATION
    DOCUMENTS
    DATASHEET ENGLISH

    |

    CHINESE
    USER'S GUIDE CHINESE
    ACCESSORIES
    STANDARDS

    ATL501C

    ATL501C

    四端开尔文夹

    ATL508B

    ATL508B

    ATL508B

    ATL805

    ATL805

    锂电池

    ATUSB

    ATUSB

    TYPEC

    TYPEC

    Type-c

    OPTIONS
    NONE
    SOFTWARE
    NONE
    Contact Anbai
    Your name*
    Your company*
    Your phone number (+Country Code)
    Your email*
    Content*
    RELATED PRODUCTS

    Compare

    AT2811

    • Test Functions: L,C,R,Z,D,Q
    • Accuracy: 0.25%
    • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
    • Measurement Range: Auto/Hold, 6 ranges
    • Measurement Speed: SLOW: 3 times/s, FAST: 10 times/s

    Compare

    AT2816A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05%
    • Measurement Frequency: 50Hz~200kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT2816B

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05%
    • Measurement Frequency: 10Hz~200kHz (37 Frequency points)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT2817

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.05%
    • Measurement Frequency: 50Hz~200kHz (16 Points)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40/10/3 times/s

    Compare

    AT2817A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.05%
    • Measurement Frequency: 50/60/100/120/200/400/500/1k/2k/4k/5k/10k/20k/40k/100kHz
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40/10/3 times/s

    Compare

    AT2818

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.05%
    • Measurement Frequency: 10Hz~300kHz (Resolution 0.01Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 3 times / 10 times / 5 times / 3 times/s

    Compare

    AT3810A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: SLOW/MED: 0.05%; FAST: 0.1%
    • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT3816A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05% ±5 digits
    • Measurement Frequency: 10Hz~200kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT3817A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: ‌0.05% ±5 digits
    • Measurement Frequency: 10Hz~100kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT3818

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: SLOW/MED: ‌0.05% ±5 digits,FAST: 0.1%
    • Measurement Frequency: 10Hz~300kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 40 times/s, 10 times/s, 3 times/s

    Compare

    AT610D

    • Test Functions: C,D
    • Accuracy: 0.1%
    • Measurement Frequency: 100Hz,120Hz,1kHz,10kHz
    • Measurement Range: AUTO/HOLD 6 Ranges
    • Measurement Speed: 3times/s, 8 times/s, 20 times/s

    Compare

    AT810

    • Test Functions: L,C.R,Z,D,Q
    • Accuracy: 0.1%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
    • Measurement Range: AUTO/HOLD, 6 Ranges
    • Measurement Speed: 15 times/s, 5 times/s, 3 times/s

    Compare

    AT810A

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg DCR
    • Accuracy: 0.05%
    • Measurement Frequency: 10Hz~20kHz (Resolution 0.001Hz)
    • Measurement Range: AUTO/HOLD/NOMINAL 9 Ranges
    • Measurement Speed: 30 times/s, 10 times/s, 3 times/s

    Compare

    AT810D

    • Test Functions: Cs-Rs,Cs-D,Cp-Rp,Cp-D,Lp-Rp,Lp-Q,Ls-Rs,Ls-Q,R-X,Z-θrad,Z-θdeg
    • Accuracy: 0.2%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz
    • Measurement Range: AUTO/HOLD/NOMINAL 6 Ranges
    • Measurement Speed: 2 times/s, 5 times/s

    Compare

    AT817D

    • Test Functions: L,C,R,Z,D,Q
    • Accuracy: 0.1%
    • Measurement Frequency: 50Hz,60Hz,100Hz,120Hz,1kHz,10kHz,
    • 20kHz,40kHz,50kHz, 100kHz
    • Measurement Range: AUTO/HOLD 6 Ranges

    Compare

    AT825

    • Test Functions: L,C,R,Z
    • Accuracy: 0.2%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz,10kHz
    • Measurement Range: -
    • Measurement Speed: 4 times/s, 1.5 times/s

    Compare

    AT826

    • Test Functions: L,C,R,Z
    • Accuracy: 0.2%
    • Measurement Frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
    • Measurement Range: -
    • Measurement Speed: 4 times/s, 1.5 times/s

    Compare

    AT2617

    • Test Functions: Cs-Rs, Cs-D, Cp-Rp, Cp-D, Rs-Q,Rp-Q, Z-D, Z-Q
    • Accuracy: 0.1%
    • Measurement Frequency: 100, 120, 1kHz, 10kHz, 100kHz 0.01%
    • Measurement Range: Auto, manual and standard , 9 range
    • Measurement Speed: 30t/s, 10t/s, 3t/s

    Compare

    AT828

    • Test Functions: C-D, C-Q, C-R, L-D, L-Q, L-R, L-Rdc, R-Q, R-X, R-Rdc, Rdc, Z-D, Z-Q, Z-θr, Z-θd
    • Accuracy: 0.2%
    • Measurement Frequency: 50Hz, 100Hz,120Hz,1kHz,2kHz,10kHz,100KHZ
    • Measurement Range: Automatic and manual
    • Measurement Speed: Slow speed 2.5 times/second, fast speed 10 times/second


    👩‍🦰Lucy@applent.com
    Wechat&Whatsapp+86 18625285980 whatsapp

    Email

    Email
    lucy@applent.com

    Send Message

    Privacy | Term of Use | Help
    ©2005-2025 Changzhou Applent Instruments Ltd. 苏ICP备13026254号