| Measurement Functions | AC/DC Withstanding Voltage & IR |
| Interface | 8-CH/RS232/Handler/LAN |
| Arc Detection | 9 Levels (AC/DC) |
| Other Functions | LIST Edit Discharge Function 5“ LCD + Touch panel |
| AC Withstand Voltage | ● |
| Rate Ouput | AC 5.000kV/10mA |
| Output Voltage | AC 0.050kV-5.000KV |
| Voltage Accuracy | 2% of reading + 5 digits |
| Output Regulation | 2% of reading +5V |
| Output Frequency | 50Hz/60Hz |
| Measurement Current | 0.001mA-10.00mA Resolution: 0.001 / 0.01 |
| Current Accuracy | 2% of reading + 5 digits |
| Rising Time | 0.1s-999.9s |
| Testing Time | 0.2s-999.9s |
| Falling Time | 0.1s-999.9s |
| DC Withstand Voltage | ● |
| Rate Output | DC 6kV/5mA |
| Output Voltage | 0.050kV-6.000kV DC Resolution: 1V |
| Voltage Accuracy | 2% of reading + 5 digits |
| Output Regulation | 2% of reading +5V |
| Current Measurement | 0.1μA-5.000mA |
| Current Accuracy | 2% of reading +5 digits |
| Rising Time | 0.1s-999.9s |
| Testing Time | 0.2s-999.9s |
| Falling Time | 0.1s-999.9s |
| Insulation Resistance | ● |
| Rate Output | DC 1kV/10GΩ |
| Output Voltage | 0.050kV-1.000kV DC Resolution: 1V |
| Voltage Accuracy | 1% of reading + 2 digits |
| Measurement Range | 0.1MΩ-10GΩ |
| IR Accuracy | <500V: 0.1MΩ-1GΩ, Accuracy:±(10% of reading +5 digits ) 1GΩ-10GΩ , For reference only ≥ 500V: 1MΩ-1GΩ, Accuracy:±(5% of reading +5 digits) 1GΩ-10GΩ, Accuracy:±(10% of reading +5 digits) |
| Testing Time | 0.2s-999.9s |
| Power Supply | 198V ~ 242V 50/60Hz 400VA |
| Dimension & Weight | 428mm( W )x89mm( H )x470mm ( D ) 14kg |
| Accessories | ATL900E-1 High voltage test rod ATL900E Withstand voltage test line ATL108 RS232 Communication |