AT4508 Multi-Channel Temperature Meter
ACTIVE
Send Email to us
RS232USB-232
SCPIMODBUS
DATA LOGGERUSB-DISK
OVERVIEW
    AT4508 multi-channel temperature meter is a new upgraded with ARM micro processor. multi-channel sampling and parallel test, can sampling, alarm and communication transmission to 8 channels simultaneously. compatibility various kinds of temperature sensors, fast response, data stable and with Break even detection function.

    The temperature test resolution 0.1 ℃.

    AT4508 support K/N/E/J/T/R//S/B thermocouples. test temperature -1200℃ to 1300℃.

    AT4508 with RS-232 & USB interface, data collection,alalysis and printing by connection PLC.

    The instrument is equipped with RS-232 interface and USB interface as standard, and provides free communication. Data collection, analysis and printing can be easily realized through PC software.

    AT4508 uses a sturdy and anti-vibration shell, which can work in harsh environments. Fully isolated digital and analog signals, ## (can be live test (isolation voltage 230Vrms, 330VDC)) ##, safe and reliable. AT4508 comes standard with U disk interface and supports real-time data storage.
FEATURES
  • Scan speed: Fast/Med/Slow
  • Cold Junction Compensation
  • TFT True Color LCD Display.
  • Interface: RS232C and USB Slaver Interface
  • USB-Disk Interface
  • Automatic detection of burnout
  • Specified channel scan
  • AT45 data acquisition software
SPECIFICATIONS
SensorThermocouple:J/K/T/E/S/N/B/R
Accuracy‌±0.2% ±2 Digits (Excluding Thermocouple)‌
Range-200℃~1800℃ (variation depend on sensor)
Resolution0.1℃
Channels8 channels; 128 channels are available
Speedfast: 500ms/channel, slow: 1s/channel
CorrectionError correction for each channel
Comparatorhigh & low beep function for each channel
InterfaceRS232C, U-disc, USB
SoftwareATS45 data acquisition software
Cold JunctionAccuracy: 0.5℃
Other FunctionsTFT-LCD True color display, broken thermocouple check function
Power SupplyV: 90VAC~260VAC Fre:47.5-52.5Hz Power:10VA
Dimension & Weight264x107x350mm weight:3kg
Accessories‌8 pcs Type K Thermocouples, 2m Length (One Set); ATL108 RS232 Communication Cable; ATN2 USB Adapter Box; ATS45 Data Acquisition Software; USB Flash Drive (1 pc)
APPLICATIONS
    Suitable for multi-point temperature testing by manufacturers and quality inspection departments in home appliances, motors, electric heating appliances, thermostats, transformers, ovens, thermal protectors, power supplies, lighting, electricity, LEDs and other industries
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS

ATL103

ATL103

USB通讯线

ATL108

ATL108

RS232通讯电缆

ATL109

ATL109

ATL109

ATN2

ATN2

OPTIONS

ATN4508

ATN4508

8路外接模块

SOFTWARE
AT45/47 Datalogger Software
Rev.6.31

Application

FREEWARE

5.3MB

RAR

AT42/45/47 Datalogger Software
Rev.8.03

Application

FREEWARE

6.3MB

MSI

Contact Anbai
Your name*
Your company*
Your phone number (+Country Code)
Your email*
Content*
RELATED PRODUCTS

Compare

AT4108

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4310

  • Sensor: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on sensor)
  • Range: -200℃~1300℃ (varying depend on sensor)
  • Resolution: 0.1℃
  • Channels: RTD 5 channels; thermocouple 10 channels; scan channel can off arbitrarily

Compare

AT4320

  • Sensor: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on sensor)
  • Range: -200℃~1300℃ (varying depend on sensor)
  • Resolution: 0.1℃
  • Channels: RTD 10 channels; thermocouple 20 channels; scan channel can off arbitrarily

Compare

AT4340

  • Sensor: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on sensor)
  • Range: -200℃~1300℃ (varying depend on sensor)
  • Resolution: 0.1℃
  • Channels: RTD20 channels; thermocouple 40 channels; scan channel can off arbitrarily

Compare

AT4516

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4724

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4724V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4732V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4740V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4748V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4756V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4764V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 16 channels;

Wechat
+86 18625285980

Wechat
+86 18625285980
Whatsapp
+86 18015292628 whatsapp

Email

Email
lucy@applent.com

Send Message

Privacy | Term of Use | Help
©2005-2025 Changzhou Applent Instruments Ltd. 苏ICP备13026254号