AT4724H Multi-Channel Temperature Meter
ACTIVE
Send Email to us
USB-232LAN
RS232RS485OPTIONS
SCPI
DATA LOGGERUSB-DISK
OVERVIEW
    AT47H series (AT4708H, AT4716H, AT4724H, AT4732H,) multi-channel temperature tester with high-performance ARM microprocessor control, 7-inch color LCD display, touch screen operation, easy to view temperature values, temperature changes Curves, histograms, etc., can collect multi-channel temperature data at the same time, super-super alarm and communication transmission, AT47 series can collect 64-channel temperature data, compatible with K/N/E/J/T/R/S/B Type thermocouple, fast response, stable data, and fault detection. Each channel can be set individually and independently corrected.

    The instrument supports RS-232 communication, and data acquisition, analysis and printing can be realized through the standard computer software. Support USB disk storage for real-time storage of sampled data. Users can independently correct each data.

    The AT47H series uses fully isolated digital and analog signals, ## (Channel segregation of voltage 2000 v , safe and reliable.
FEATURES
  • 7 inches TFT true color LCD display
  • Histogram display, graph
  • Highest value, lowest value, average value display
  • Cold junction compensation
  • Standard USB disk interface, support for large-capacity storage devices.
  • Standard RS232C interface and USB interface
  • Automatic detection of broken couple
  • Specified channel scan
  • Standard data acquisition software
SPECIFICATIONS
SensorJ/K/T/E/S/N/B/R
Accuracy‌±0.2% ±2 Digits (Excluding Thermocouple)‌
Range-200℃~1800℃(
Resolution0.01℃
Channels24 channels
SpeedFast: 500ms, Slow:1s
CorrectionEach channel error collection
ComparatorUpper and lower alarms, each channel can be set separately
InterfaceRS232C, U-disc, Type-c,LAN
SoftwareATS47 data collection sofware
Cold JunctionAccuracy:0.5℃
Other FunctionsTFT-LCD true color LCD display, burnout detection function, histogram display, curve graph, upper limit value, lower limit value, average value display
Power SupplyV: 100VAC~240VAC Fre:47.5-52.5Hz Power:10VA
Dimension & Weight294*130*316mm/ 3 kg
Accessories‌24 pcs Type K Thermocouples, 2m Length (Three Sets of 8 pcs)‌,TYPE-C Communication Cable;ATS47 Data Acquisition Software
APPLICATIONS
    Suitable for multi-point temperature testing of manufacturers and quality inspection departments in home appliances, motors, electric appliances, thermostats, transformers, ovens, thermal protectors, power supplies, lighting, electric power, LED, etc.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATL109H

ATL109H

ATL109H

TYPEC

TYPEC

Type-c

OPTIONS
NONE
SOFTWARE
AT45/47 Datalogger Software
Rev.6.31

Application

FREEWARE

5.3MB

RAR

Contact Anbai
Your name*
Your company*
Your phone number (+Country Code)
Your email*
Content*
RELATED PRODUCTS

Compare

AT4108

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4310

  • Sensor: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on sensor)
  • Range: -200℃~1300℃ (varying depend on sensor)
  • Resolution: 0.1℃
  • Channels: RTD 5 channels; thermocouple 10 channels; scan channel can off arbitrarily

Compare

AT4320

  • Sensor: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on sensor)
  • Range: -200℃~1300℃ (varying depend on sensor)
  • Resolution: 0.1℃
  • Channels: RTD 10 channels; thermocouple 20 channels; scan channel can off arbitrarily

Compare

AT4340

  • Sensor: RTD:PT100/Cu50, thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: RTD 0.2℃±2,thermocouple:0.5%±0.5℃ (varying depend on sensor)
  • Range: -200℃~1300℃ (varying depend on sensor)
  • Resolution: 0.1℃
  • Channels: RTD20 channels; thermocouple 40 channels; scan channel can off arbitrarily

Compare

AT4508

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4516

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4732H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4724

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4724V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4732V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4740V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4748V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4756V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4764V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 16 channels;

Compare

AT4816

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channels; 128 channels are available

Compare

AT4824

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4832

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Wechat
+86 18625285980

Wechat
+86 18625285980
Whatsapp
+86 18015292628 whatsapp

Email

Email
lucy@applent.com

Send Message

Privacy | Term of Use | Help
©2005-2025 Changzhou Applent Instruments Ltd. 苏ICP备13026254号