    AT47AV series multi-channel temperature tester adopts high-performance ARM microprocessor control, 7-inch color LCD screen display, touch screen operation, convenient to view temperature value, temperature change curve, histogram, etc., can simultaneously collect multi-channel temperature data. Ultra-low alarm and communication transmission, AT47AV series can collect 64 channels of temperature data, compatible with K/N/E/J/T/R/S/B thermocouples, fast response speed, stable data, and has a broken couple detection function . Each channel can be set individually and calibrated independently.

    The instrument supports USBcommunication, and data collection, analysis and printing can be realized through standard computer software. Support USB disk storage, real-time storage of sampling data. The user can independently correct each channel of data.

    The AT47AV series adopts fully isolated digital and analog signals, ## (can be tested on-line (isolation voltage 230V rms, 330VDC), support PT100, CU50, safe and reliable.
FEATURES
  • 7 inches TFT true color LCD display
  • Histogram display, graph
  • Highest value, lowest value, average value display
  • Cold junction compensation
  • Standard USB disk interface, support for large-capacity storage devices.
  • Standard RS232C interface and USB interface
  • Automatic detection of broken couple
  • Specified channel scan
  • Standard data acquisition software
SPECIFICATIONS
SensorThermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
Accuracy±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
Range-200℃ ~1800℃(The testing range varies depending on the sensor)
Resolutionthermocouple:0.01℃ ; thermal resistance:0.01℃
Channels32CHS
SpeedSlow 1s,Medium 500ms
CorrectionError correction for per channel
ComparatorUpper and lower overload alarms; Set up upper and lower overshoots separately for each channel
InterfaceLAN interface, TYPE-C communication and USB, as well as optional RS485 and wireless network module
SoftwareATS45 data acquisition software
Cold JunctionAccuracy 0.5℃
Other FunctionsTFT-LCD true color LCD display; Broken couple detection function; Display of numerical values, bar charts
and curves;Display of the average value of the upper and lower limit values; Standard 64G super large
memory;
Power SupplyV: 100VAC~240VAC Fre:47.5-52.5Hz Power:10VA
Dimension & Weight294x130x316mm weight:3kg
AccessoriesATL109D Each thermocouple is 2 meters long (thermocouples corresponding to the number of channels are provided with the equipment)
TYPE-C communication cable; ata acquisition software;
APPLICATIONS
    Suitable for multi-point temperature testing of manufacturers and quality inspection departments in home appliances, motors, electric appliances, thermostats, transformers, ovens, thermal protectors, power supplies, lighting, electric power, LED, etc.
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE CHINESE
ACCESSORIES
STANDARDS

ATL108

ATL108

RS232通讯电缆

ATL109D

ATL109D

ATL109D

TYPEC

TYPEC

Type-c

OPTIONS
NONE
SOFTWARE
AT42/45/47 Datalogger Software
Rev.9.11

Application

FREEWARE

6.3MB

MSI

Contact Anbai
Your name*
Your company*
Your phone number (+Country Code)
Your email*
Content*
RELATED PRODUCTS

Compare

AT4108

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4116

  • Sensor: Thermocouple:J/K/T
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16channels;

Compare

AT4202

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: 0.2%+1℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 2 channels

Compare

AT4204

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 4 channels

Compare

AT4208

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels

Compare

AT4508

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels; 128 channels are available

Compare

AT4516

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channel; 128 channels are available

Compare

AT4524

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels; 128 channels are available

Compare

AT4532

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels; 128 channels are available

Compare

AT4708

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 16 channels

Compare

AT4724H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃(
  • Resolution: 0.01℃
  • Channels: 24 channels

Compare

AT4732H

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 32 channel

Compare

AT4808

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 8 channels;

Compare

AT4724

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 32 channels;

Compare

AT4740

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 48 channels

Compare

AT4756

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 56 channels;

Compare

AT4764

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4708V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4724V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4732V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor),
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4740V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4748V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4756V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4764V

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R,PT100,CU50,DCV
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌;PT100: ±0.6℃ CU50 : ±0.6℃
  • Range: -200℃~1800℃ (variation depend on sensor)
  • DCV:100mV~100V
  • Resolution: 0.01℃

Compare

AT4716

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 16 channels;

Compare

AT4816

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 16 channels;

Compare

AT4824

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 24 channels;

Compare

AT4832

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 32 channels;

Compare

AT4540

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 40 channels; 128 channels are available

Compare

AT4548

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 48 channels; 128 channels are available

Compare

AT4556

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 56 channels; 128 channels are available

Compare

AT4564

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 64 channels; 128 channels are available

Compare

AT4572

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 72 channels; 128 channels are available

Compare

AT4580

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 80 channels; 128 channels are available

Compare

AT4588

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 88 channels; 128 channels are available

Compare

AT4596

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 96 channels; 128 channels are available

Compare

AT45104

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 104 channels;

Compare

AT45112

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 112 channels; 128 channels are available

Compare

AT45120

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 120 channels; 128 channels are available

Compare

AT45128

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.1℃
  • Channels: 128 channels; 128 channels are available

Compare

AT4708A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4708AH

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4708AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 8CHS

Compare

ATQ4901

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R;PT100;PT1000(optional)
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 200 channels;‌(Customizable number of channels, incremented/decremented by 10 channels each time)

Compare

ATQ4900

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 200 channels;‌(Customizable number of channels, incremented/decremented by 10 channels each time)

Compare

AT4708AD

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels~64 channels

Compare

AT4716A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 16 channels;

Compare

AT4724A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 24 channels;

Compare

AT4732A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4740A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 40 channels;

Compare

AT4748A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 48 channels;

Compare

AT4756A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 8 channels;

Compare

AT4764A

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃ (variation depend on sensor)
  • Resolution: 0.01℃
  • Channels: 64 channels;

Compare

AT4716AH

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4724AH

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4732AH

  • Sensor: J/K/T/E/S/N/B/R
  • Accuracy: ‌±0.2% ±2 Digits (Excluding Thermocouple)‌
  • Range: -200℃~1800℃
  • Resolution: 0.01℃
  • Channels: 8 channels

Compare

AT4716AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 16CHS

Compare

AT4724AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 24CHS

Compare

AT4740AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 40CHS

Compare

AT4748AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 48CHS

Compare

AT4756AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 56CHS

Compare

AT4764AV

  • Sensor: Thermocouple:J/K/T/E/S/N/B/R; Added support for PT100; CU50; DCV; PT1000 (optional)
  • Accuracy: ±0.2%±2 dgt(Excluding thermocouples); PT100: ±0.6℃ CU50 : ±0.6℃ ; PT1000: ±0.6℃
  • Range: -200℃ ~1800℃(The testing range varies depending on the sensor)
  • Resolution: thermocouple:0.01℃ ; thermal resistance:0.01℃
  • Channels: 64CHS

微信客服


👩‍🦰Lucy@applent.com
Wechat&Whatsapp+86 18625285980 whatsapp 👩🏻queena@applent.com
Wechat&Whatsapp+86 13775247528 whatsapp

Email

Email
lucy@applent.com
queena@applent.com

Send Message

Privacy | Term of Use | Help
©2005-2026 Changzhou Applent Instruments Ltd. 苏ICP备13026254号